Assembly Buildings 2 & 3 (AB2 & AB3)

Assembly Buildings 2 and 3 (AB2 & AB3) are designed to provide dedicated build-up and checkout space for customer payload and booster systems. Below are the key features and functionalities of these assembly buildings:

Facility Specifications

  • Build-Up and Checkout Space
    Provides a dedicated area for the assembly and testing of customer payload and booster systems.
  • Front Office Space
  • High Bay Area
    • Dimensions: 29 ft x 35 ft, offering sufficient space for operational activities.
    • 8 x 8 Access doors.
    • Secure facility.
  • Climate Controlled
    Both buildings are climate-controlled to ensure optimal working conditions for sensitive operations.
  • Retractable Ordnance Grounds
    Equipped with retractable ordnance grounds for safety and compliance during assembly processes.
  • Visual Surveillance
    Continuous visual surveillance of the high bay area to enhance security and monitoring.

Communication and Access

  • Communication
    Integrated communication panel for effective communication during operations.
  • Access Doors
    Each building is equipped with two access doors, each measuring 8 ft x 8 ft, facilitating easy entry and exit.

Crane Facilities

  • Monorail Cranes
    Two monorail cranes with capacities of 2 tons and 3 tons, featuring a hook height of 10.5 inches for efficient material handling.

Explosive Load Limits

  • AB2 Explosive Load Capacity
    The explosive load limit for Assembly Building 2 (AB2) is 4,630 lbs. (Class 1.1).
  • AB3 Explosive Load Capacity
    The explosive load limit for Assembly Building 3 (AB3) is 30,000 lbs. (Class 1.1).